Torque unit convertion

Torque convertion table
Units to be=mN*m=cN*m=N*m=ozf*in=lbf*in=lbf*ft=gf*cm=kgf*cm(kp*cm)=kgf*m(kp*m)
1 mN*m10.10.0010.1420.0090.000710.20.010.0001
1 cN*m1010.011.4160.0880.0071020.1020.001
1 N*m10001001141.68.8510.7381019710.20.102
1 ozf*in7.0620.7060.00710.06250.005720.0720.0007
1 lbf*in11311.30.1131610.0831152.11.1520.0115
1 lbf*ft1356135.61.3561921211382613.830.138
1 gf*cm0.0980.010.00010.0140.00090.0000710.0010.00001
1 kgf*cm(kp*cm)98.079.8070.09813.890.8680.072100010.01
1 kgf*m(kp*m)9807980.79.807138986.87.2331000001001

Conversion formula: units to be converted x factor = corresponding unit
Example: 5 lbf*ft = ? cN*m Solution: 5 x 135.6 = 678 cN*m
Other examples:
1 N*m = 0.102 kgf*m
1 N*m = 0.7386 lbf*ft
1 N*m = 8.851 lbf*in

Torque unit converter
 = 

Selection of necessary tightening torque

Suggested tightening torque
Pitch of bolt[mm]
Fill out the dimension here

ClassTensile strength Rm [N/mm^2]Elastic limit Rp 0.2 [N/mm^2]Lubr. typeTightening moment [N*m]
8.8800640u=0.10
u=0.12
u=0.14
10.91000900u=0.10
u=0.12
u=0.14
12.912001080u=0.10
u=0.12
u=0.14
u=0.10 - MoS2 greased
u=0.12 - electro galv. 8 um
u=0.14 - not greased
Core diameter of thread[mm]
Effective diameter of thread[mm]
Hexagonal height of nut[mm]
Hex head size[mm]
Height of washer[mm]
External diameter of washer[mm]
Internal diameter of washer[mm]
Nominal diameter of thread[mm]
Stress area[mm^2]
Hexagon socket size[mm]
Hexagon socket screw thread[mm]
All data under reservation. We don't assume liability for none correct data.